Before powering up the scale card power supply make sure all wiring is correct. If any rewiring or re-splicing is needed make sure to power off scale card power supply.
Entire process is done on internal interface
Go to scale menu (4) to scale layout (1):
- Channel 1 – silo 1
- Channel 2 – silo 2
- Channel 3 – scale 1
- Channel 4 – scale 2
Go to scale menu (4) to test (8), check AD readings:
- Silos = 1500-15000 AD
- Scales = 15000-20000 AD (with platform hanging)
If AD readings are in range above go to scale menu (4) to calibration (9).
Bird Scale:
Make sure there is an inch of clearance between scale platform and bedding. Place cursor on channel 3 for bird scale 1 and follow steps below.
- Press enter to go into calibration mode. Make sure bird scale is empty before proceeding to next step.
- Press enter for tare registration. After tare wait 5 seconds.
- Place 5 lbs weight on bird scale (make sure to place the weight gently so the scale does not swing).
- On the control enter the weight, wait 5 seconds and press enter.
- Remove weight and press menu.
- Place cursor on channel 4 for scale 2 and repeat process.
- Repeat steps 1-6 for channel 4 Scale 2
Bin Scale:
Make sure there is no feed in the bin. Make sure there is an inch clearance from bin leg to concrete. Place cursor on channel 1 for silo scale 1 and follow steps below.
- Press enter to go into calibration mode. Make sure nothing is placed on bin legs/crossbars.
- Press enter for tare registration.
- Place (8) 45 lb weights on bin crossbars and press enter.
- On control enter weight (360 lbs) and press enter.
- Remove weights and press enter.
- Enter current bin weight (zero) and press enter.
- Press menu.
- Place cursor on channel 2 for silo2.
- Repeat steps 1-7 for channel 2 Silo 2
Comments