This table describes the outputs and their related relays. In case there is a problem check the following before troubleshooting your unit:
- Voltage
- Circuit breakers
- All other connections
After verifying that the above are operating, follow the instructions given in the table below.
General Troubleshooting Issues
Issue # | Issue Description | Related Relay |
1 | Inlet open1 power fails | Replace K2 |
2 | Inlet open2 fails | Replace K3 |
3 | Tunnel open power fails | Replace K5 |
4 | Fan 1 & 2 fails | Replace K16 |
5 | Fan 3 & 4 fails | Replace K17 |
6 | Fan 5 & 6 fails | Replace K18 |
7 | Fan 7 & 8 fails | Replace K19 |
8 | Fan 9 & 10 fails | Replace K20 |
9 | Fan 11 & 12 fails | Replace K21 |
10 | Fan 13 & 14 fails | Replace K22 |
11 | Fan 15 & 16 fails | Replace K23 |
12 | Heater 1 & 2 fails | Replace K24 |
13 | Heater 3 & 4 fails | Replace K25 |
14 | Cool Pad 1 & 2 fails | Replace K26 |
15 | Cool Pad 3 & 4 fails | Replace K27 |