Functionality
- Control/Ventilation
- Ventilation Types
- Other Functions
- System
- Management
- History
- Measurement & Calibration & Test
- Installation
Control/Ventilation
| Trio 20 Swine | |||
| Functionality | 7.2.4 | R5.0.23 | R4.2.11 |
| Temperature Curve Set | V | V | V |
| Min/Max Ventilation Set | V | V | V |
| Minimum Ventilation Level at Extra/Tunnel mode | V | V | V |
| Air Quality (RH%, CO2, NH3) | V | V | V |
| Static Pressure Inlet/Tunnel | V | V | V |
| Heaters | V | V | V |
| Cooling | V | V | V |
| Sprinkling | V | V | V |
| Timers | V | V | V |
| Timers control by outside temperature | V | V | X |
| Ventilation levels | V | V | V |
| Inlet & Curtain Levels | V | V | V |
| Inlet & Curtain Levels Disable per level | V | V | V |
| Min/Max ventilation control by Outside temperature | V | V | V |
| Ventilation control by Wind Chill factor | V | V | V |
| Minimum Ventilation fan rotation | V | V | V |
| Cycling Extra/Tunnel fans | V | X | X |
| Brooding | V | V | V |
| Pre-heat with negative days | V | V | X |
| Separate zone\central heating system | V | X | X |
| Heaters ignition time support | V | X | X |
| Heating in special house modes | V | X | X |
| Central Exhaust (30 levels) | V | V | V |
| Central Exhaust Cooling | V | V | V |
| Central Corridor | V | V | V |
| Vario Inlet/Fresh Air Distributor Solution | V | V | V |
| Measuring Fan and Ventilation Compensation | V | V | V |
Ventilation Types
| Functionality | 7.2.4 | R5.0.23 | R4.2.11 |
| Minimum | V | V | V |
| Transitional | V | V | V |
| Tunnel | V | V | V |
| Basic Stir | V | V | V |
Other Functions
| Functionality | 7.2.4 | R5.0.23 | R4.2.11 |
| Water management | V | V | V |
| Feeding management | V | V | V |
System
| Functionality | R7.2.4 | R5.0.23 | R4.2.11 |
| Sequential deployment of output device at Power up | V | V | X |
Management
| Functionality | 7.2.4 | R5.0.23 | R4.2.11 |
| Alarm Settings | V | V | V |
| Alarm Test | V | V | X |
| Alarm Reset | V | V | V |
| Batch Management | V | V | V |
| Animal Curve Settings | V | V | V |
| Silo Management | V | V | V |
| Load/Save settings | V | V | V |
| Access control | V | V | V |
History
| Functionality | 7.2.4 | R5.0.23 | R4.2.11 |
| Temperature | V | V | V |
| Humidity | V | V | V |
| Water | V | V | V |
| Cooling Water | V | X | X |
| Water/Feed Conversion | V | X | X |
| Feed | V | X | X |
| Heaters | V | V | V |
| Alarms | V | V | V |
| Events | V | V | V |
| Last 24 Hrs | V | V | V |
| CO2 | V | V | V |
| Ammonia | V | V | V |
| Silo Weighing | V | X | X |
| Mortality | V | V | V |
| Power Consumption | V | V | V |
| Gas Consumption | V | V | V |
Measurement & Calibration & Test
| Functionality | 7.2.4 | R5.0.23 | R4.2.11 |
| Temperature | V | V | V |
| Humidity | V | V | V |
| CO2 | V | V | V |
| Ammonia | V | V | V |
| Static Pressure | V | V | V |
| Water | V | V | V |
| Silo Weighing directly with load cell | V | X | X |
| Potentiometer | V | V | V |
| Outside Temperature measurement sharing between controllers at the farm | V | V | V |
| Power Meter | V | V | V |
| Gas Meter | V | V | V |
| Sensors testing & troubleshooting | V | X | X |
Installation
| Functionality | 7.2.4 | R5.0.23 | R4.2.11 |
| Setup | V | V | V |
| Relay Layout | V | V | V |
| Relay Expansion 10 | V | V | V |
| Relay Expansion Disable Mode | V | V | X |
| Analog Sensors | V | V | V |
| Digital Sensors | V | V | V |
| Analog/Digital Sensors Disable Option | V | X | X |
| Analog Output | V | V | V |
| Vent\Curt Setup | V | V | V |
| Temp Definition | V | V | V |
| Temp Sensor Location | V | X | X |
| Scales (Silo) | V | X | X |
| RSU-2 Remote Scale Units | V | X | X |
| Device Properties | V | V | V |
Devices by Version
| Devices/Sensors | Trio 20 Swine – R7 | Trio 20 Swine – R5 | ||||||||||||
| Total No per Room/House | Output | Measurements | Output | Measurements | ||||||||||
| Total | Relay | 0-10V | Comm | Analog | Digital | Comm | Total | Relay | 0-10V | Analog | Digital | Comm | ||
| Cooling | 2 | 2 | 2 | 2 | ||||||||||
| Cooling Central Exhaust | 2 | 2 | 2 | 2 | ||||||||||
| Heaters | 6 | 6 | 6 | 6 | 6 | 6 | ||||||||
| Inlets | 2 | 2 | 2 | 2 | 2 | 2 | ||||||||
| Outlets | 1 | NA | 1 | 1 | NA | 1 | ||||||||
| Tunnel Doors/Curtains | 2 | 2 | 2 | 2 | 2 | 2 | ||||||||
| Fans Exhaust/Tunnel | 20 | 20 | 8 | 20 | 20 | 8 | ||||||||
| Fans Central Exhaust | 20 | 20 | 8 | 20 | 20 | 8 | ||||||||
| Stir Fan | 1 | 1 | 1 | 1 | 1 | 1 | ||||||||
| Sprinkler | 1 | 1 | 1 | 1 | ||||||||||
| Timer | 5 | 5 | 5 | 5 | ||||||||||
| Feeder | 1 | 1 | 1 | 1 | ||||||||||
| As Relay | 20 | 20 | NA | 20 | 20 | NA | ||||||||
| As Analog Output | 8 | NA | 8 | 8 | NA | 8 | ||||||||
| Alarm | 1 | 1 | 1 | 1 | ||||||||||
| Temperature Sensors | 12 | 12 | ||||||||||||
| Humidity Sensors IN | 1 | 1 | ||||||||||||
| Humidity Sensors OUT | 1 | 1 | ||||||||||||
| CO2 Sensors | 1 | 1 | ||||||||||||
| Ammonia Sensors | 1 | 1 | ||||||||||||
| Pressure Sensors | 1 | 1 | ||||||||||||
| Potentiometers | 4 | 4 | ||||||||||||
| Silo Weighing | 3 | NA | ||||||||||||
| Water Meters | 4 | 4 | ||||||||||||
| Aux. Input | 4 | 4 | ||||||||||||
| Feeder Line Sensor | 1 | 1 | ||||||||||||
| Power Meter | 2 | 2 | ||||||||||||
| Gas Meter | 3 | 3 | ||||||||||||
| RSU-2 Remote Scale Unit | 2 | NA | ||||||||||||