Author: Michael Ginsburg
Date: December 5th 2023
Summary
This release includes following features:
- Extended Sensors testing & troubleshooting (appendix B)
- Cycling tunnel/extra fans (appendix C)
- Separate zone\central heating system (appendix D)
- Heaters ignition time support (appendix E)
- Temperature sensor location (appendix F)
- Heating in special house modes (appendix G)
- History for Cooling water usage and cool pad runtime
- Variable Fan capacity calculation (Min & Max attributes)
- Network notification status
- Trio batch history (saved at the controller) Excel file generation
- Devices test duration
- Piglet heat Zone control
- History for Cooling Central Exhaust
- Support for Vietnamese UI
- Improvement on:
- Stopping zone heater when reaching the target temperature (8088)
- Inlets opening on different percentage, while inlets are operated at the same (7987)
- Trio support ID presentation (6801)
- Analog fan "device” attributes presentation (7734)
- Water overflow alarm limit of 5000 (7321)
- White screen appearance (7595)
- System restart (7618)
- Level cycle time settings limitation (7538)
- Trio Temperature graph display on dashboard (7227)
- Outside temperature sensor reading sharing with other Trio’s (8083)
- Ventilation Settings Update
- House settings 3D drawing presentation (5374)
- Online updates message presentation
- Silo 1 calibration last page presentation
- Fixing "Data display error" message, that might appear for few seconds
- Columns Title lockup during the scroll down (5820)
- Ammonia and CO2 PPM Units presentation at dashboard and climate history table (5677)
- Support ID registration
- Ventilation cold maximum value limitation (6771)
- Fan rotation functionality after enable/disable of fan cycle
- Main board backup battery usage, while powered on
- Inlet closing functionality during cycle off time (7528)
- Internal memory operation stability and notifications, while performing the controller settings read or edit/save operations
- Central heat in extra/tunnel functionality
- Air quality functionality
- Cooling history recording
- Improvement on:
Release Specification
Product Name | Trio |
Software Version | Trio 7.2.4 |
Supported Hardware | Trio Main CPU, Trio UI CPU |
Communicator-2 Trio Software | Communicator-2 Trio 1.1.02 |
Release Date | 05-Dec-23 |
Supported Languages | English, Italian, Danish, Swedish, German, Spanish, Portuguese, Russian, Chinese, Korean, Japanese, Thai, Hebrew, Arab, Turkish, Vietnamese |
SW Update Issues
- The SW version rollback is supported for the Version 5.0.23 or higher
- The update package performs the SW upgrade for both Trio Main CPU, Trio UI CPU
- The update is available online while connected to WEB
- USB Disk should be used for the offline updates
- It’s recommended to use USB update method in case of poor Internet quality
- The special proceedings should be performed for the smooth transition to version R5/ (see Appendix A)
- R7 Version download file size is 1.2 GB (takes around 2 minutes within 100 Mbit Internet connection)
Notes
- There is a known anomalies list (see below), which will be fixed within future versions
Known Anomalies
Ventilation & Control
Description | Workaround |
When 2 of Inlets/Tunnel doors are Controlled by Pressure and first inlet/tunnel door reaches full opening , the second inlet/tunnel door does not open and High Pressure Alarm is triggered | Avoid operating 2 of Inlets/Tunnel doors controlled by Pressure. Use just 1 set of inlets/Tunnel doors controlled by Pressure. |
Vents are pre-opened according to the current level learned value, but not by the forthcoming level pre-open value | Comptroller will readjust the opening according to the target pressure |
When operating controller in Dual Room mode and Room #2 doesn’t have Humidity sensor, the Room 2 Dashboard shows Humidity Sensor reading from Room 1 | Control still operates based on the Room2 settings without Humidity Sensor. |
Settings & Backup
Description | Workaround |
Adding a new row at Min/Max Ventilation Table might take some time | Wait until the operation completes |
When the user upgrades the Trio SW version and loads a backup file, the history information of Animal Management and the current number of animals are not saved | Keep the history record at other media |
While performing Trio Upgrade, Trio might get to initial page when Swine Poultry selection should be made. Then a previously saved backup file might not be available for selection. | Select New Setup without Backup file loading. When controller finished upgrade process, load backup file. |
Test & Calibration
Description | Workaround |
Starting a device test in “Devices & Sensors” menu always changes the device’s state to OFF even if it was ON. | The test operation can still be used. When exiting the test mode (or 5 minutes after the test mode was entered) the device operates properly according to the controller’s reselected state |
While performing Relay Test for Inlet or Tunnel Door, the % of opening does not change at Dashboard | Recalibrate the Inlet/Curtain |
Auto calibration process doesn't work with less than 5 steps | Set the number of steps value higher than 5 |
Analog output fan capacity attribute might get zeroed, while performing test for that specific fan. |
Reenter manually Analog output fan capacity attribute |
Alarms
Description | Workaround |
When deploying Auxiliary Alarm, the Validation of Related Relay does not operate within the Expansion Box relay | Do not set AUX alarm related relay in the expansion box |
History
Description | Workaround |
After uninstalling one of the water meters, water history table might display "N/A" for an existing meter | Disregard the history of uninstalled water meters |
When Outside Temp and Humidity sensors are not activated, the History shows the values of 0°C and 0% instead of showing N/A value | 0°C and 0% records in the History table should be considered as N/A |
When the user upgrades the Trio SW version and loads a backup file, the history information might be out of order | Do not upgrade in the middle of the flock. |
Comments
0 comments
Please sign in to leave a comment.