The following section details how to use the Activity Log, in particular how to determine who made changes to the controllers’ settings. Please note:
- These inquiries can only be made via the web. Local connections or connecting via TeamViewer do not support this function.
- Only changes made via the web are listed! Changes made locally by the farm owner or administrator are not listed.
- Only administrators can perform this function.
1. Connect to a farm via www.rotemnetweb.com.
2. Under the settings icon, click Farm Settings.
3. Click the Activity Log tab.
4. Define as needed:
- Gateway Name (farm name that the user chose): Read only.
- From/To: Define the time frame.
- Event:
- To see all events, leave this field empty.
- To see who made changes to the controller settings, chose Save Farm Data from the dropdown list.
- Sub Event: Select if required.
- User: If you are looking for a specific person’s activities, type in the user name.
- Cmd ID: If you are looking for a specific change in controller settings, type in the command ID. See the list in the following table.
In the following example Event is defined as Save Farm Data. User ben made the following changes:
- 85: History feed
- 66: Fan air capacity
- 21: Event DB Property
- 27: Temp & Timer Setting
- 11: VOID (Reserved)
CMD ID and Description | ||
1: Version Old | 3: VOID | 4: Signature |
7: Active Alarm | 9: VOID | 11: VOID |
12: Bird Inventory - READ | 13: VOID | 14: VOID |
15: VOID | 17: CO2 Treatment STD | 18: VOID |
19: Dosing Pump | 20: PCI | 21: Event DB Property |
23: VOID | 24: Ammonia Treatment STD | 25: Relay Current |
27: Temp & Timer Setting | 28: STD | 29: VOID |
30: Stir Fan Level | 31: VOID | 32: VOID |
33: VOID | 34: VOID | 35: VOID |
36: VOID | 37: VOID | 38: Light Feed |
39: Water and Feed | 40: Extra System | 41: Static Pressure Standard |
42: Static Pressure Precision | 43: Control Mode | 44: Bird Curve |
45: History Setup | 46: Levels Of Ventilation | 47: Feed Calibration |
48: Water Calibration | 49: Setup | 50: Relays Layout |
51: Analog Sensors | 52: Digital Sensors | 53: Temp Definition |
54: Curtains Setup | 55: Vent And Curtain Level | 56: Sys CO2 Treatment STD |
57: System Parametes | 58: Bird Scale Setting Bre As Bro | 59: Alarm Settings |
60: Sys Ammonia Treatment STD 9 | 61: Stir Fan Program | 62: VOID |
63: VOID | 64: Analog Output | 65: Temperature Reminder |
66: Fan Air Capacity | 67: VOID | 68: Speed Fan Levels |
69: Feed Bin Settings | 70: Data Plug | 72: Relays Test |
73: VOID | 74: Daily DB Property | 75: Cage |
76: EggRoomSetPoint | 77: VOID | 78: VOID |
81: Sys Nest | 83: History Temperature | 84: History Humidity |
85: History Feed | 87: History Alarams | 88: SSC Plug Play |
90: Sys_ControlMode | 92: Week Of Flock | 93: Time |
94: VOID | 96: SRP HUB HW | 97: Feed Inventory |
98: Last 100 Weights | 99: Set THI | 101: Temp Curve |
102: Set Rad Heater | 103: Vent Level Set Point | 104: Set stir fan |
105: Static Pressure Set Point | 106: Set Cool Pad | 107: Set Point Foggers |
108: Set Humidity Treatment | 109: Set Soft Min/Max Level | 110: VentAndCurtainLevels Set Point |
111: Light Set parameters | 112: Active Silo | 113: Emergency Set Point |
114: VOID | 115: Sys Minimum Vent | 116: Set Relay Current |
117: Bird Inventory - WRITE | 118: VOID | 119: Alarm DB Property |
120: RDT Table | 122: Test Analog Input | 123: Test Digital |
124: VOID | 125: RDT Set Table | 126: SSC HD |
127: Het Key - Temperature Sensors | 128: FeedQuantityUpdate | 130: VOID |
131: VOID | 132: VOID | 133: VOID |
134: CO2 Set Point | 135: Sys Water and Feed | 137: VOID |
138: VOID | 139: VOID | 140: VOID |
141: History System Events | 142: Set Bird Scale Setting BreAsBro | 143: WorkRoomControl |
144: EggRoom | 145: VOID | 146: CO2 Treatment |
147: Feed Conversion | 148: SRP Hub Plug And Play | 149: Light No Feed |
150: History View DB Property | 151: New History View | 152: Set Dosing Pump |
153: Levels Of Ventilation - Read Only | 154: Min/Max Level By Weight | 155: Set Point of Min/Max Level By Weight |
156: Set Point Scale Laout | 157: MinVent & Ramping Set point | 158: Fogger Set Point (STD) |
159: Fogger STD | 160: Variable Speed Fans Setting | 162: STD Curtain Set up |
163: set.Std_V_Speed_Fans | 164: Stir Fan Set program | 165: Water On Demand |
166: Sys variable heat | 194: Feed Scale Program | 206: Light No Feed |
207: Light Feed | 208: Water And Feed | 215: Auger Layout |
216: Water And Feed By Quantity from 5.05 | 217: Water And Feed By Quantity | 218: Set Curve |
222: Set Natural Program | 224: Natural Program | 225: Ammonia Treatment |
228: Service Wind Direction | 231: Ammonia Treatment SetPoint | 235: Feed Line Calibration |
236: Set Floor Heat | 237: Light Dimmer Comm | 238: Water and Feed SetPoint |
239: Set Water On Demand | 243: Minimum Vent Timer STD | 244: Timer Settings STD |
247: Temp And Timer Settings STD | 248: Sys Humidity TreatmentSTD | 249: Sys Curtain Calibration |
255: Hot Key Natural | 256: Hot Key - Lights | 257: Munters Drive |
258: Water Meters | 260: Web OverView | 261: Dash Board |
262: Switches Change Confirm | 263: Switche Status Array | 264: Status Bar |
265: Temp Reminder | 266: System Security | 267: Signatures |
270: ReciveOnce | 271: EggRoomHistory | 272: HK EggRoom |
273: HumidityFactorComm | 274: WaterAndFeedBreeder | 276: History Egg Belt |
277: Fast Main Screen | 278: Hot Key - Water & Feed | 279: History Egg Counter |
280: HK Egg Counter | 284: History Ammonia | 285: Hot Key - Analog Output |
286: SetPoint Feed Scale | 287: HK Feed Scale | 288: Scale Clibration |
290: Scale Layout | 291: Emergency Set Comm | 293: Hot Key - Scales |
294: Set Analog Output | 295: Feed Scale Program | 296: Hot Key Feed Bin |
298: Feed Scale Setting | 299: HK_FeedScale | 300: Hot Key - Temperature & Humidity |
301: Hot Key - Curve | 302: Water and Feed Set Mem23 | 303: Hotkey Zoon Inlet |
304: Hot Key - Infra Red | 305: VOID | 306: Nest table |
307: Hot Key - Curtains | 308: Bird Weight Bre As Bro | 309: Scale History Bre |
311: Bird Weight Bre Auto | 312: Web Weight | 313: Control Level By Weight Hot Key |
314: Scale Test | 315: FDQ Tab 1 | 318: HK Pump Dosing |
319: TableWarning | 320: Heather Duration | 321: Power Consumption |
322: History Heaters | 323: History Mortality | 324: History Water |
325: SSC Power Consumption | 326: SSC HK | 327: FDQ Tab 2 |
328: History Variable Heaters | 329: Hot Key Cool Ramping | 330: Dosing Pump |
331: Dosing Pump History | 332: History Table Of Events | 333: History Radiant Heaters |
334: Power Meter HK | 335: Munters Drive HK | 336: Scale History |
337: CO2 History | 338: SRP Hub |
Comments
4 comments
Dear Support
I contact you from A.Mintikkis Farm, Nicosia Cyprus.
We face a problem with a Comunicator 2.0.
All of a sudden it asks us to activate the farm again but when I fill in the details
and press activate it says ( Save Gateway Error! )
I did the Internet tests and they are OK, removed the battery but still the same.
Please see the attached photos. Also can you reply on email: akis@mintikkis.com.cy
Please see the attached photos.
Hello Petros - thank you for contacting us - please let me know the best time for you to have a call so we will be able to help you with the issue you have
all the best
support team
Hello Yanir,
At 11:00 will be fine. Do I need to be at the farm near the comunicator?
I am Akis the technician. My phone number is +35799643148
Please sign in to leave a comment.